Prepared inclusion complexes were characterized by Fourier transf

Prepared inclusion complexes were characterized by Fourier transform infrared spectroscopy, differential scanning calorimetry (DSC), and X-ray diffraction (XRD) studies. In vitro PFTα ic50 dissolution study was performed using phosphate buffer pH 6.4, distilled water, and HCl buffer pH 1.2 as dissolution medium. The optimized inclusion complex was studied for its bioavailability in rabbit and the results were compared with those of pure cilostazol and Pletoz-50. Phase solubility study showed dramatic improvement in the solubility of drug by formation of complexes, which was further increased by

pH adjustment. The dissolution rate of cilostazol was markedly augmented by the complexation with DM-beta-CD. DSC and XRD curves showed sharp endothermic peaks indicating the reduction in the microcrystallinity of cilostazol.

Selected inclusion complex was also stable at ambient temperature up to 6 months. The in vivo study revealed that DM-beta-CD increased the bioavailability of cilostazol with low variability in the absorption. Among all cilostazol-cyclodextrins complexes, cilostazol-DM-beta-CD inclusion complex Z-IETD-FMK ic50 (1:3) prepared by coprecipitation method showed 1.53-fold and 4.11-fold increase in absorption along with 2.1-fold and 2.97-fold increase in dissolution rate in comparison with Pletoz-50 and pure cilostazol, respectively.”
“Tortuosity can be described as the variation in blood vessel curvature. Abnormal

tortuosity is an important clinical indicator of various conditions. Despite considerable research, there has been very little agreement on an accurate, unique measure of this phenomenon for clinical applications. It has been demonstrated that a single value is insufficient to describe vessel tortuosity. In this work, the fast Fourier transform of the vessel’s curvature as a measure of tortuosity is introduced. Spectral analysis of a suite of computed-simulated vessels, a phantom and clinical data is carried out. Observation of the acquired spectra permits detection of the local curvature variations. Spectral analysis of curvature provides a compact and graphic representation of tortuosity. This paper also describes two new highly automated MATLAB algorithms selleck products for obtaining the vessel centrelines: a heuristic image processing algorithm, and an algorithm based on the probabilistic Hough transform. We demonstrate the accuracy of both algorithms comparing with a manual method to extract the vessel centreline. Both algorithms reduce potential errors and user time and only require the manual selection of one centroid. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.”
“Indigenous Bacillus pumilus, B. licheniformis, and B. subtilis were isolated from marine water and soil samples and investigated for potential bioremediation ability in Penaeus monodon culture. Bacillus spp.

Comments are closed.